News | Events | Investors | Careers | Contact | Register

Tel: +44 (0)870 225 1790 or +44 (0)28 9020 1050       | De | En | Es | Fr | Pt

Three Channel DC Voltage Logger the DC-3V-60

DC-3V-60 3 channel Vdc logger
You can log current and temperature using the DC-3V-60, simply select and order the appropriate transducers or DC shunts listed below, for example a DC Current sensor can be supplied to allow logging of DC currents from renewable energy sources.
 

Ideal for monitoring and recording one, two or three channels of DC voltages from 1Vdc to 60Vdc, for example from batteries, circuit breaker trip batteries, charging circuits, power supplies, photovoltaic (PV) cells, DC motor circuits, DC Generators, DC telecoms circuits...  We can extend the range to 400Vdc, just let us know. Using appropriate transducers or signal conditioners, you can record many parameters, temperature, solar irradiation, wind speed,....

All Electrocorders use a constant sampling technique, meaning they sample every cycle multiple times, missing very little data! Many, many other brands do not, they simply sleep for 99.99% of the time, waken to take a sample, then sleep; they miss 99.99% of the data! How can you perform a survey when 99.99% of the data is missing?

DC-3V-60-KIT includes logger (1), unfused voltage input leads (4), USB lead (1), 12Vdc PSU (1), software (1) and carry case (1).

DC Current (Split) Transducers (22mm cable):-
DK100 B10, 50, 75 or 100Adc, 0-10Vdc, £165.
DK200 B10, 100, 150 or 200Adc, 0-10Vdc, £165.
DH-B420L B, BIDIRECTIONAL, 500A to 2kA models, 4-20mA, £165.
 
 Split Core AC/DC Transducer
AC/DC Current (Solid) Transducers (32mm cable):-
DK20 C10
, 5Adc, 10Adc or 20Adc, 0-10Vdc, £165.
DHR100 C10 1Aac/dc to 100Aac/dc, 0-10Vdc, £120.
DHR200 C10 1Aac/dc to 200Aac/dc, 0-10Vdc, £120.
DHR300 C10 1Aac/dc to 300Aac/dc, 0-10Vdc, £155.
DHR400 C10 1Aac/dc to 400Aac/dc, 0-10Vdc, £155.
DHR500 C10 1Aac/dc to 500Aac/dc, 0-10Vdc, £155.
DHR600 C10 1Aac/dc to 600Aac/dc, 0-10Vdc, £155.
 
DHR1000 C10 1Aac/dc to 1kAac/dc, 0-10Vdc, £165. 
Solid Core AC/DC Transducer
DC Current Shunts available:-
55A/50mV Datel (3020-01097-0) Shunt (circa £20)
100A/50mV Datel (3020-01099-0)Shunt (circa £20)
500A/50mV Datel (3020-01103-0) Shunt (circa £25)
Current Shunt 
Pyranometers (Solar Radiation) available:-
SP Lite2, Kipp & Zonen, to 2000W/m2 (circa £300)
Current Shunt 
Outside Air Sensors with Radiation Shield:-
EC-TT532-CVO, Sontay, 0-10Vdc output (circa £70)
Current Shunt 

WEEE Compliance.
For EU customers Acksen Ltd offer a product take-back service. For customers within the European Union (only) and products manufactured or sold by us; when those products reach the end of their life, simply send them back to us at your expense, we will dispose of them according to the relevant legislation.



Back